1. Introduction
Non-steroidal anti-inflammatory drugs can relieve pain and edema to play a role in the treatment of inflammation, however, patients taking non-steroidal anti-inflammatory drugs often cause gastritis, gastric ulcer, kidney and liver damage and other adverse symptoms.[1] Mobic is one of the non-steroidal anti-inflammatory drugs [2] and the structural formula is shown in Figure 1. The toxic and side effects of Mobic are much less than those of some other non-steroidal anti-inflammatory drugs (such as dotaline, ibuprofen, etc.). Therefore, the adverse effect of Mobic on gastrointestinal function was much smaller [3] .This drug is widely used in daily life and it is a very common drug for the treatment of rheumatoid arthritis. in addition to the treatment of inflammatory diseases, Mobic also has a good effect on relieving physical pain in patients [4].
Lipase is a hydrolase that decomposes triacylglycerol. It is an intracellular enzyme. Its catalytic site contains a nucleophilic catalytic triad (SHD or SHE). The catalytic site is buried inside the molecule and the surface is formed by relatively hydrophobic amino acid residues. Covered by a spiral lid structure to protect the catalytic part of the triplet [5]. Human lipase is mainly secreted by pancreatic acinar cells, so it is also called pancreatic lipase, and plays a role in digesting fat in the duodenum. It plays an important role in the absorption of triglycerides in the small intestine. Hydrolyzed triglyceride is converted into Glycerin and fatty acids are absorbed by the body [6] and play an important role in the process of digestion and absorption. Zhao Lining et al. [7] studied the interaction of three mercaptopropionic acid-terminated CdTe quantum dots with lipase, and proved that three mercaptopropionic acid-terminated CdTe quantum dots can cause toxic side effects on lipase; Zhang Rui et al. [8] studied the interaction of bisphenol A with lipase in vitro to better understand the toxicity and toxicity mechanism of bisphenol A.
In recent years, fluorescence spectroscopy has become an important means to study the mechanism of ligand-protein system. But up to now, researches on the interaction of lipase with Mobic have not been reported by a variety of spectroscopic and computer simulations.In this paper, the binding constants, binding sites, thermodynamic parameters and binding distance of the drug-protein system were obtained by spectroscopic experiments and molecular docking methods, and a series of experimental data such as binding constants, binding sites, thermodynamic parameters and binding distance were obtained. Thus, the mechanism of Mobic binding to lipase is revealed, which provides important information for more comprehensive understanding of the mechanism of drug and protein transport and harmony in human body.
2. Experimental
2.1 Apparatus
RF-5301PC fluorometer (Shimadzu, Japan); UV-3600 UV-vis spectrophotometer (Shimadzu, Japan); MOS-450/SFM300 circular dichroism (Bio-Logic, France); SYC-15Bsuper constant temperature water bath (Nanjing Sanli Electronic equipment Factory); SZ-93 automatic double Pure Water Distiller (Shanghai Yarong biochemical instrument Factory).
2.2 Materials
Porcine pancreatic lipase (PPL, purity grade inferior 99%, Sigma), reserve solution (5.0 × 10 − 6mol/L); Mobic (CAS#,71125-28-7), reserve solution(4.0 × 10 − 4mol/L). Tris-HCl buffer solution was used to keep the pH of the solution at 7.40, and NaCl (0.10 mol/L) solution was used to maintain the ionic strength of the solution. The water used in the experiment was secondary quartz distilled water, and the above storage solution was kept away from light at 277 K. The fluorescence signal measured in the experiment was corrected by the "internal filter effect" Equation (1) [9]:
$$\begin{aligned}
Fcor = Fobs \times {e^{({A_{ex}} + {A_{em}})/2}}
\end{aligned}
\label{eq1}$$(1)
Where Fcor and Fobs are the corrected and observed fluorescence signals, respectively, and Aex and Aem are the absorbance values of Mobic-PPL system at excitation and emission wavelengths, respectively. The fluorescence signal used in this article was corrected.
2.3 Experiment procedure
2.3.1 Fluorescence experiment
At 298K, 310K and 318K, 1.0 mL Tris-HCl buffer solution, 2.0 mL PPL solution and different volume of Mobic solution were added to the 10.0 mL colorimetric tube at constant volume and constant temperature of 30 min. The slit width was 5 nm, λex and the scanning fluorescence spectra were 280, 295 nm, respectively.
2.3.2 Circular dichroism measurements
At 298K, 1.0 mL Tris-HCl buffer solution, 2.0 mL PPL solution and different volume of Mobic solution were added to the 10.0 mL colorimetric tube at constant volume and constant temperature of 30 min. Circular dichroism measurements were performed with a 1.0 cm path length quartz cuvette. Each spectrum was recorded at wavelengths between 190 and 300 nm and a scan speed of 1 nm/s.
2.3.3 UV-Vis measurements
At 298 K, 1.0 mL Tris-HCl buffer solution, 2.0 mL PPL solution and different volume Mobic solution was added to the 10.0 mL colorimetric tube at constant volume and constant temperature of 30 min. The absorbance of the system was determined by using the corresponding concentration of Mobic solution as the blank reference, and the UV absorption spectrum of the system was drawn.
2.3.4 Molecular docking
The crystal structure (PDB ID: 1RP1) of PPL comes from the protein database (Protein Data Bank). The ChemDraw Pro 14.0 and ChemBio 3D Ultra 14.0 are used to draw the Mobic structure, and the energy minimization of the three-dimensional structure is carried out. AutoDock 4.2.6 was used to study the molecular docking of Mobic and PPL, and genetic algorithm was used to calculate the binding conformation of Mobic and PPL [10].
3. Results and discussion
3.1 Fluorescence quenching mechanism studies of Mobic-PPL system
The fluorescence effect of protein is produced by the chromophore of Trp, Tyr and Phe residues. The Trp and Tyr residues in protein are excited together at 280 nm wavelength, while at 295 nm wavelength, only Trp residue is excited [11]. Figure 2 showed the fluorescence spectra of the interaction between Mobic and PPL (at λex=295 nm, the fluorescence spectra of Mobic and PPL are similar, but the fluorescence intensity was low). Figure 2 showed that the fluorescence peak of PPL at 343 nm quenched and the emission peak had a blue shift with the increase of Mobic concentration, indicating that the Mobic-PPL system interacted and formed a stable complex [12].
The Stern-Volmer [13] equation was shown below, through which the quenching constant Ksv and the quenching rate constant kq: can be calculated by using the fluorescence signal data obtained from the experiment:
$$\begin{aligned}
{F_0}/F = 1 + {k_q}{\tau _0}[L] = 1 + {K_{SV}}[L]
\end{aligned}
\label{eq2}$$(2)
Where F0 and F represent the fluorescence signals in the absence and presence of quencher, respectively. τ0 is the average lifetime of fluorescence without quencher, which is about 10 − 8 s. Ksv is the Stern-Volmer quenching constant. kq is the bimolecular quenching constant, and [L] is the concentration of Mobic.If the quenching mechanism of the binding system is single, then the relationship curve between F0/F and [L] is linearly correlated [14]. The Stern-Volmer equation curve of Mobic-PPL system was shown in Figure 3. From Figure 3, it could be seen that the relative fluorescence intensity F0/Fof PPL and the concentration of quenching agent Mobic showed a good linear relationship, and the linear correlation coefficient is more than 0.99. It reflected the existence of a single quenching mechanism.
The results were shown in Table 1. The results showed that the kq values at different temperatures are larger than the maximum diffusion collision quenching constant of 2 × 1010L/mol ⋅ s [15] for biomolecules by various quenching agents. At the same time, it could be seen from the data in Table 1 that with the increase of temperature, kq of Mobic-PPL system and Ksv’s are decreased. The results showed that the quenching mode of Mobic-PPL system was static quenching.
For static quenching, the Equation (3) [16] is generally used to calculate the binding constant Ka and the number of binding sites n:
$$\lg \left( {\frac{{{F_0} - F}}{F}} \right) = n\lg {K_a} + n\lg \left\{ {\left[
L \right] - n\frac{{{F_0} - F}}{{{F_0}}}\left[ {{B_t}} \right]} \right\}
\label{eq3}$$(3)
[Bt] represents the concentration of PPL, and the results were shown in Table 1. From Table 1, n ≈ 1 at the experimental temperature indicates that there is only one high affinity binding site [17] for Mobic to bind to PPL, that is, Mobic formed a 1:1 complex with PPL. The binding constant Ka of Mobic to PPL decreased with the increased of temperature, which further proved that the fluorescence quenching type of Mobic-PPL system was static quenching. Figure 4 showed the participation of Tyr residues and Trp residues of PPL in Mobic-PPL system. The results showed that when λex=280 nm and λex=295 nm, the quenching curve of Mobic-PPL system was separated. This indicates that both Tyr residues and Trp residues in PPL participated in the reaction. However, the slope of the quenching curve of Mobic-PPL system at λex=295 nm was obviously smaller than that of the binding system at λex=280 nm, which indicated that the fluorescence quenching degree of PPL was stronger at λex=280 nm.
3.2 Type of interaction force of Mobic-PPL system
The thermodynamic parameters of Mobic-PPL system were calculated according to van’t Hoff equation [18], and the calculated results were shown in Table 2.
$$Rln K = ΔS − ΔH/T$$(4)
$$ΔG = − RTln K = ΔH − TΔS$$(5)
Where R is a gas constant (ΔH and ΔS with a value of about 8.314), Mobic and PPL can be calculated by a linear relationship between the natural logarithm (lnKa) of the binding constant and the reciprocal (1/T) of the temperature. The results were shown in Table 2. It can be seen from Table 2 that ΔG<0 indicated that the binding reaction between Mobic and PPL was spontaneous, and ΔH<0 indicated that the formation of Mobic-PPL complex was exothermic.The arrangement of water molecules creates a more random configuration around drugs and proteins in a more orderly manner. Therefore, ΔS>0 is usually used as evidence of hydrophobic interaction between drug molecules and protein molecules [19,20]. Based on this, the hydrophobic interaction between Mobic and PPL can be judged.
3.3 Circular dichroism spectra studies of Mobic-PPL system
As one of the well-known biophysical techniques, circular dichroism spectrum (CD) is usually used to clarify the secondary structure of proteins. In the CD spectrum, the far ultraviolet region (180 nm) mainly shows the α-helix, β-fold and irregular crimping of the protein [21]. The peaks at the left and right sides of the 208 nm and 222 nm are characteristic peaks of α-helix. The change of α-helix content can be obtained by using the following formulas [22]:
$${K_{\alpha - Helix}}(\% ) = \frac{{ - {N_{MRE}} - 4000}}{{33000 - 4000}} \times
100
\label{eq6}
%(6)$$(6)
The NMRE is the molar ellipticity at 200 nm; the number 4000 is the NMRE value of β-fold and random curl at 200 nm; and the number 33000 is the NMREvalue of pure α-helix at 200 nm.
$${N_{MRE}} = \frac{{{I_{CD}}}}{{10{C_P}nl}}
\label{eq7}
%(7)$$(7)
In the equation, n is the total number of amino acids in PPL, about 450, l is the light diameter of the sample cell (cm), Cp is the concentration of protein, and ICD is the intensity of CD peak. The circular dichroism spectroscopy of Mobic-PPL system was shown in Figure 5. When the molar ratio of PPL to Mobic are 1:0, 1: 10 and 1: 20, the content of α-helix structure of PPL molecules decreased from 17.65% to 4.24%. The intensity of the negative peaks decreases gradually and without obvious change in position and shape of the peaks. It can be concluded that the interaction between Mobic and PPL made the α-helix structure of PPL loose and changed the protein secondary structure, leading to quenching of the PPL fluorescence. But α-helical structure was still dominant.
3.4 UV-vis absorption spectra studies of Mobic-PPL system
UV-vis absorption spectra can be used to explore the structural changes of proteins and to study the formation of protein-ligand complexes [23]. Figure 6 was an absorption spectrum of the Mobic-PPL system. From the Figure 6, it can be seen that PPL has two absorption peaks, and its strong absorption peak near 208 nm reflects the frame conformation of the protein. The weak absorption peak at about 280 nm is due to aromatic amino acids (Trp, Tyr and Phe) [24]. With the increases of Mobic concentration, Figure 6 showed that the intensity of the absorption peak at 208 nm decreases with the blue shift, and the absorption peak at 280 nm also decreases slightly. This result indicated that the interaction between Mobic and PPL led to the formation of new complexes, and the PPL molecule tended to fold, the hydrophobicity of PPL microenvironment was enhanced.The shift of UV-Vis absorption spectra indicated that the fluorescence quenching of PPL by Mobic was a static quenching process [25], which was consistent with the results of fluorescence experiments.
3.5 Binding distance of Mobic-PPL system
According to Förster’s non-radiative energy transfer theory, when the transfer efficiency is 50%, the distance between the donor (r) and the recipient (R0) and the energy transfer efficiency (E) can be calculated by the following formula:
$$E = 1 - F/{F_0} = {R_0}^6/({R_0}^6 + {r^6})$$(8)
$$R_{0}^{6}=8.79 \times 10^{-25} K^{2} \Phi N^{-4} J$$(9)
$$J = \sum {F(\lambda )\varepsilon } (\lambda ){\lambda ^4}\Delta \lambda /\sum F
(\lambda )\Delta \lambda$$(10)
In the combination system, the recipient is the PPL, donor is the Mobic, whereF is the fluorescence intensity of recipient in the presence of the same concentration of donor, K2 is the orientation factor, Φ is the fluorescence quantum yield of the donor without the recipient, N is the refractive index at this wavelength, F(λ) is the fluorescence intensity of the fluorescence donor at wavelength λ, and ϵ(λ) is the molar absorptivity of the acceptor at that wavelength.Under these experimental conditions, it is reported that K2= 2/3, N=1.336 and Φ = 0.15 [26 ].J is the overlap integral between the fluorescence emission spectrum of the donor and the absorption spectrum of the recipient, as shown in Figure 7.
The values of J, E, R0 and r are calculated in turn by formula and shown in Table 3. As shown in Table 3, the donor-recipient distance r<7 nm indicates a high likelihood of energy transfer from PPL to Mobic.With the increase of temperature, the distance r increases and the energy efficiency E decreases, which results in the decrease of the stability of the binary system and the decrease of the value of the binding constant Ka, which is consistent with the data obtained from the fluorescence experiment and the synchronous fluorescence experiment.
3.6 Molecular docking
Molecular docking plays an important role in exploring the interaction between ligands and receptors. In order to further determine the binding position of Mobic-PPL system and the effect of Mobic binding to PPL on ligands and receptors. In this paper, the binding model of Mobic and PPL was established by molecular docking method. By this method, the type of force and the lowest binding energy of Mobic and PPL binding system could be obtained. Figure 8(A) showed the optimal binding position of Mobic to PPL, where the Lys268 residue formed two hydrogen bonds with Mobic, with bond lengths of 2.065 Å and 1.951 Å, respectively, and Mobic formed a hydrogen bond with the Ser333 residue, and its bond length is 2.148 Å. These results showed that hydrogen bond played an important role in the binding of Mobic to PPL. Figure 8(B) showed a plurality of hydrophobic amino acid residues such as Phe335, Tyr267, Trp85 and Ieu275 around Mobic, further indicating that there was hydrophobic force in the binding process between Mobic and PPL. The amino acid residues such as Tyr267 and Trp85 were relatively close to the binding position of Mobic and PPL, which led to the binding could effectively quench the endogenous fluorescence of PPL, which was consistent with the conclusion of fluorescence quenching experiment. The active center of different lipases usually consists of serine (Ser) residues and histidine (His) residues, and together with aspartic acid (Asp) residues or glutamic acid (Glu) residues constitute a three meta catalytic center [27]. It could be seen from Figure 8(B) that the Mobic binding position was near the active center of the PPL. The results of molecular docking also showed that the binding of Mobic and PPL could change the microenvironment of the catalytic active center of PPL. In other words, the binding of the system might affect the catalytic activity of PPL.
The binding energy obtained from molecular docking for Mobic and PPL interaction was -25.86 kJ/mol. Whereas, the free energy change calculated from fluorescence quenching results was -25.11 kJ/mol at 310 K. This difference may be due to exclusion of the solvent in docking simulations or rigidity of the receptor other than Trp and Tyr residues [28]. The energy data obtained by docking the molecules were list in Table 4. From Table 4, it could be also seen that the electrostatic energy was very much lower than the sum of van der Waals energy, hydrogen bonding energy and desolvation free energy in the binding process of Mobic with PPL, indicating that the main interaction mode between Mobic and PPL was not electrostatic binding mode. Combined with the data of fluorescence experiments and the results of theoretical modeling, it could be seen that hydrophobic interaction and hydrogen bond were the main forces driving the combination of Mobic molecules with PPL molecules, which led to the static quenching of PPL.
4. Conclusion
In this study, Mobic reacted with PPL to form a 1:1 complex under simulated physiological conditions. The interaction of the binding system was investigated by spectroscopy and molecular docking techniques, and it was found that the binding of Mobic to PPL would change the conformation of PPL. It is of positive significance for the study of pharmacokinetics, pharmacodynamics and toxicology of Mobic. At present, the use of spectroscopy to study the interaction between proteins and ligands is more and more popular and favored by researchers. compared with other research methods such as chromatography, this research method has the advantages of low experimental cost and short measurement period. It has a wide range of applications, so this study provides an important reference for efficient and rapid discussion of the interaction between proteins and ligands.